Spirometry/PFT Filters
Available for most Pulmonary Function Testing Equipment
During pulmonary function testing, patients exhale bacteria and viruses. Without a filter, these contaminants enter into your PFT equipment.
Futuremed’s economical spirometry and PFT filters effectively trap 99.99% of bacteria and 99.90% of virus, protecting your equipment and preventing cross-contamination between patients.
Low resistance and dead space let you preserve the accuracy of your spirometry measurements.
|
|
Futuremed filters are available with separate plastic or cardboard mouthpieces, or with built-in oval ones.
Most filters come in adult and pediatric sizes.
ASK US FOR A FREE SAMPLE
VIRAL EFFICIENCY
|
|
BACTERIAL EFFICIENCY
|
Mean filtration efficiency
|
99.90%
|
|
Mean filtration efficiency
|
99.99%
|
Flow rate
|
20 L/M
|
|
Flow rate
|
20 L/M
|
Challenge material rating
|
Biosafety No. 1
|
|
Challenge material rating
|
Biosafety No. 2
|
Mean particle
|
5.0µM
|
|
Mean particle
|
5.0µM
|
Challenge matter
|
Bacteriophage øX174
E-COLI Strain C
|
|
Challenge matter
|
Staphylococcus aureus
|
Incubation interval
|
5 hours
|
|
Incubation interval
|
40 hours
|
Incubation temperature
|
37 ºC ± 2 ºC
|
|
Incubation temperature
|
37 ºC ± 2 ºC
|
FLOW PERFORMANCE DATA
|
Dead space
|
<58 ml
|
Flow resistance (@ 12 L/sec)
|
.40 cm-H20/L/sec
|
Flow resistance (@ average 0-12 L/sec)
|
.16 cm-H20/L/sec
|
|
PART # |
DESCRIPTION |
39NA-025 |
25 PFT filters (fit Discovery, SpiroVision-3+ and Spiropalm spirometers. No adapter needed.) |
39NA-050 |
50 PFT filters (fit Discovery, SpiroVision-3+ and Spiropalm spirometers. No adapter needed.) |
39NA-100 |
100 PFT filters (fit Discovery, SpiroVision-3+ and Spiropalm spirometers. No adapter needed.) |
39NA-250 |
250 PFT filters (fit Discovery, SpiroVision-3+ and Spiropalm spirometers. No adapter needed.) |
39295 |
50 PFT filters (fit Spirobank. Vacumed, MIR, Creative Biotech and many others spirometers) |
39298 |
250 PFT filters (fit Spirobank. Vacumed, MIR, Creative Biotech and many others spirometers) |
39050-02E |
50 spirometry filters with oval mouthpieces (fit Sensormedics, VMax and many other PFT instruments) |
39200-02E |
200 spirometry filters with oval mouthpieces (fit Sensormedics, VMax and many other PFT instruments) |
39295ST |
50 bacteria filters for ST-90, ST-250, ST-100, Fukuda spirometer and more. Note: The specifications of these filters is slightly different. Please contact us for more information. |
Filters are available for other brands. To ensure an exact fit call us at 1-800-222-6780.
|
|
|
|
|